Specification | GRACES-ID | ||||
Lifting height range/m | 1.5≤H≤13.0 | ||||
Use segment length/m | -- | ||||
Tilt angle/° | 30/35 | ||||
Nominal width/mm | 600/800/1000 | ||||
Nominal speed/m/s | 0.5 | ||||
Applicable environment | Indoors | ||||
The type of work | Normal type | ||||
Handrail structure | Vertical armrests | ||||
Drag method | Y-△/VVVF | ||||
Startup mode | Standard single speed Standard self-starting Frequency conversion low speed Frequency conversion self-starting | ||||
Number of horizontal steps as standard | H≤6m | 2 | |||
H>6m | 3 | ||||
Pedal depth/mm as standard | -- | ||||
Additional brakes | H≤6m | No | |||
H>6m | Yes | ||||
Truss deflection | ≤1/750 | ||||
Safety factor for moving parts | ≥5 |
Specification | GRACES-Ⅲ | ||||
Lifting height range/m | 1.5≤H≤13.0 | ||||
Use segment length/m | -- | ||||
Tilt angle/° | 30/35 | ||||
Nominal width/mm | 600/800/1000 | ||||
Nominal speed/m/s | 0.5 | ||||
Applicable environment | Outside | ||||
The type of work | Normal type | ||||
Handrail structure | Vertical armrests | ||||
Drag method | Y-△/VVVF | ||||
Startup mode | Standard single speed Standard self-starting Frequency conversion low speed Frequency conversion self-starting | ||||
Number of horizontal steps as standard | H≤6m | 2 | |||
H>6m | 3 | ||||
Pedal depth/mm as standard | -- | ||||
Additional brakes | H≤6m | No | |||
H>6m | Yes | ||||
Truss deflection | ≤1/750 | ||||
Safety factor for moving parts | ≥5 |
Specification | GRACES-LD | |||||
Lifting height range/m | 1.5≤H≤18 | |||||
Use segment length/m | -- | |||||
Tilt angle/° | 27.3/30 | |||||
Nominal width/mm | 600/800/1000 | |||||
Nominal speed/m/s | 0.5/0.65 | |||||
Applicable environment | Indoor/Outdoor | |||||
The type of work | Public transport type | |||||
Handrail structure | Vertical armrests | |||||
Stainless steel diagonal armrest | ||||||
Drag method | VVVF | |||||
Startup mode | Frequency conversion low speed Frequency conversion self-starting | |||||
Number of horizontal steps as standard | H≤6m | 3 | ||||
H>6m | 3 | |||||
Pedal depth/mm as standard | -- | |||||
Additional brakes | H≤6m | Yes | ||||
H>6m | Yes | |||||
Truss deflection | ≤1/1000 | |||||
Safety factor for moving parts | ≥5 |